Calibration: |
Single element
thermocouple type 'K' according to ANSI MC96.1 |
Type of construction: |
With densely
packed magnesium oxide insulation and ungrounded hot junction |
Sheath material: |
INCONEL 600 for
thermocouple type K |
Temperature limit: |
Thermocouple K:
1150°C |
Insulation
Resistance: |
100 M ohm with a
500 Vd.c |
Extension cable |
cable type k 2
wire awg 24 stranded mfa gs (silicon rubber) shielded |
Process connection |
1/4" gas ci |