CONNECTORS FOR EASY USE OF SEVERAL KIND OF CABLES (WITH DIFFERENT LENGTHS AND TYPE OF INSULATION) BY MEANS OF TERMINAL POTS WITH SCREWS, GRANTING A HIGH DEGREE OF PROTECTION (IP-67) |
|
|
|
|
|
Technical data |
|
|
|
|
|
Type of thermocouple |
Single element thermocouple type 'K' or 'J' according to IEC 584 class 2 (ASTM E 230) |
Connection |
Compensated male connector, plug in and screw on type, with body in moulded Nylon and M12X1 metal thread (to DIN-VDE 0627)
Degree of protection IP 67
Temperature MAX 90 °C |
Insulation resistance |
100 MOhm with a 500 V DC at room-temperature |
Temperature limit |
1150°C for thermocouple type 'K'
600°C for thermocouple type 'J' |
Sheath diameter 'd' (mm) |
ø3 / ø4.5 / ø6 |
Sheath material |
INCONEL 600 for thermocouple type 'K'
AISI 304 S.S. for thermocouple type 'J' |
Minimum bending radius |
Three times the outer diameter |
Type of construction |
With densely packed magnesium oxide (MgO) insulation and ungrounded hot junction |
Accessories |
Compensated M12 extension cables
Compensated M12 female connectors |
|
|