THERMOCOUPLES FOR MOULDS WITH METALLIC TRANSITION POT FOR HIGH TEMPERAURE
Thermocouples with MgO insulation with colored kapton cable and metallic transition pot for high temperature (T max 400°)  

Technical data
 

 
 
Type of thermocouple Single element type 'J' or 'K' (*) thermocouple according to IEC 584 class 2 (ASTM E 230)

(*) Type 'K' available on demand
Type of construction With densely packed magnesium oxide insulation and ungrounded hot junction
Sheath material Thermocouple K: INCONEL 600
Thermocouple J: AISI 304
Temperature limit Maximum temperature of operation of the sensing junction is 600°C
Maximum temperature of operation of the transition pot is 400°C
Sheath diameter 'd' d=1±0.1mm
d=1.5±0.1mm
Minimum bending radius Three times the outer diameter
Extension cable Cable type J IEC 584 2 wire cable AWG 24 stranded PTFE + Kapton Kapton
Insulation resistance Rmin=100MOhm a 100Vdc
 